What was found
REJECTED TAKE-OFF X 2 FOR LEVEL 2 "GEN DRIVE 2 FAULT ". FIRST TIME CAME ON FOR 2 SECONDS. SECOND ATTEMPT CAME ON STEADY WITH POWER AT T/O THRUST. GEN DRIVE 2 FAULT CLEARED WITH POWER REDUCED. OPENED RT SIDE NR 2 ENGINE FAN COWL TO INSPECT NR 2 ENGINE GENERATOR, FOUND GENERATOR OIL LOW, SERVICED GENERATOR, ALSO INSPECTED GENERATOR, DPI INDICATOR IS OK, NO MAJOR LEAKS FOUND ON GENERATOR WHEN COWL FIRST OPENED. CLOSED NR 2 ENGINE FAN COWLS PER MM 71-14-00, MANUAL 24-10, AND 12-12-05 IN MM, NOW DOWN TO OPS CHECK OF CSD. PERFORMED HIGH POWER RUN GEN. CHECKED GOOD.FREQS AND VOLTS NORMAL CSD OIL TEMP AND RISE TEMP GOOD AND PRESSURE NORMAL.