What was found
DURING FLIGHT GREEN SYS QUANTITY DECREASED TO TOP OF THE CAUTION ARC ON THE OVERHEAD PANEL AND ON THE ECAM. AFTER LANDING, NOTED IT RECOVERED SOME OF QUANTITY BUT WAS STILL BELOW THE TOP HAT ON OVERHEAD PANEL. REPLACED RT MLG SEQUENCE VALVE IAW AMM 32-31-37-4. STEPS A THROUGH D. UNABLE TO ACCOMPLISH STEP E, EXTENSION AND RETRACTION FUNCTIONAL TEST DUE TO NO JACKS AVAILABLE AT STA. LEAK CHECK CARRIED OUT, NONE FOUND AT THIS TIME.