What was found
MAIN DECK BS 1060, LBL 24 TO LBL 45 FLOOR SUPPORT SHIM CRACKED. CRACKED COVER PLATE AT BS 1060 REMOVED AND REPLACED IAW SRM 51-40-02 REV 98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100 CRITERIA.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN DECK BS 1060, LBL 24 TO LBL 45 FLOOR SUPPORT SHIM CRACKED. CRACKED COVER PLATE AT BS 1060 REMOVED AND REPLACED IAW SRM 51-40-02 REV 98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100 CRITERIA.