What was found
RT WING LWR T/E, FALSE SPAR IS CRACKED AT INBD END, WBL 118. REMOVED LWR CHORD SECTION IAW DWG 27-57-038 REV C & DOUBLER IAW DWG SR27-57-038 REV C. TRIMMED OUT INBD AREA IAW DWG SR27-57-038, REV C & FABRICATED 2 ANGLES & HEAT TREATED ANGLES TO T6 IAW ER NR 2-37153-801 REV A. FABRICATED NEW WEB SECTION IAW DWG NR SR27-57-038 REV C & FABRICATED NEW CHORD IAW DWG NR SR727-52-038 REV C. FABRICATED STRAP IAW DWG NR SR27-57-038 REV C & FABRICATED 2 RADIUS FILLER IAW DWG NR SR27-57-038 REV C. FABRICATED NEW DOUBLER IAW DWG SR27-57-038 REV C. TREATED & PRIMED REPAIR PARTS & INSTALLED ALL IAW SRM 51-30-2, SRM 51-30-2, AND DWG NR SR27-57-038, REV C.