What was found
MAIN DECK, BELOW FLOOR-CORROSION ALONG BOLT LINE AT STA. 1370 BETWEEN UPRIGHTS R4 AND R9. WHERE THE SLANT PANEL MEETS THE UPPER AFT END OF THE WING BOX. REMOVED AND REPAIRED CORROSION AS REQUIRED, REF SRM 51-21-01 AND E.A. 8-5710-130986 (AFT UPPER SKIN-RT UPPER SURFACE CORROSION REWORK), WORK CARD SEQ. 24.