What was found
MAIN CABIN FLOOR STR STA 326, RBL 5 HAS AREA OF CORROSION. (OUT OF LIMITS) REMOVED FLOOR SUPPORT BS 324-345, RBL5 IAW SRM 51-40-02. CHECKED LIMITS & FOUND TO BE OUT OF LIMITS IAW SRM 53-00-04, FIG. 101, DETAIL 2. ORIG THICKNESS; .100" AFTER REWORK; .085" REMOVED; .015". REMOVED GALLEY FITTING ON SUPPORT BS 324, RBL 5 IAW SRM 51-40-02 FOR ACCESS. FABRICATED NEW SUPPORT IAW SRM 51-40-02. LOCATED AND DRILLED SUPPORT IAW SRM 51-40-05. REMOVED 4 EA STIFFNERS, FOR ACCESS, IAW SRM 51-40-02. TREATED AND PRIMED SUPPORT IAW SRM 51-20-01. PAINTED SUPPORT IAW AMM 51-21-00-7. INSTALLED FLOOR SUPPORT, STIFFNERS, AND GALLEY FITTING, IAW SRM 51-40-02. THIS IS A CAT "A" MAJOR REPAIR.