As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
MAIN CABIN FLOOR STR STA 307 RBL 4 HAS AREA OF CORR. (OUT OF LIMITS) BLEND OUT AREA IN FLOOR SUPPORT STRAP, MAT. BEFORE .100 AFTER REWORK .088 FOUND OUT OF LIMITS IAW SRM 53-0004 FIG. 101 DET. 2, REPLACED WITH NEW FABRICATED STRAP IAW SRM 51-40-02 THIS IS A MAJOR "A" REPAIR WITH NO FOLOW-UP INSPECTIONS REQUIRED.