What was found
MAIN CARGO AREA, BS 450, STR 3L, NO EDGE DISTANCE BETWEEN FASTENERS. REMOVED FASTENERS AREA IAW SRM 51-30-2, CUT OUT DAMAGE STRINGER AREA IAW SRM 53-10-3 FIG 3, FABRICATED FILLER. FABRICATED PLATE NR 1. FABRICATED PLATES NR 2 IAW SRM 53-10-3 FIG 3 53-10-2 FIG 9 TREATED AND PRIMED PARTS IAW SRM 51-10-2 AND INSTALLED REPAIR PARTS IAW SRM 53-10-3 AND 51-30-2.