What was found
AFT PIT FLOORBOARD SUPPORT UPPER SURFACE HAS CORROSION APPROX FROM STA 1440 TO STA 1500 AT LBL 4. REMOVED CORROSION IAW SRM 51-10-02. CHECKED LIMITS. ORIG MAT THICKNESS 0.063 AFTER REWORK 0.042. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-83. REMOVED FLOOR SUPPORT AND SPLICE IAW SRM 51-40-02. FABRICATED FLOOR SUPPORT. LOCATED AND DRILLED FLOOR SUPPORT IAW SRM 51-40-05. TREATED AND PRIMED FLOOR SUPPORT IAW SRM 51-20-01. INSTALLED NUTPLATES IAW SRM 51-40-02. INSTALLED FLOOR SUPPORT AND SPLICE IAW SRM 51-40-02. THIS IS A MINOR REPAIR.