What was found
FUSELAGE SKIN PROTRUDING DENT STA 1440 STR 24L. EVALUATED DENT AND FOUND OUT OF LIMITS IAW SRM 53-00-01, REMOVED LINER AND INSULATION FOR ACCESS IAW MM 25-52-003 AND 25-50-007-4. CUT OUT DAMAGED AREA DIM 7/8" IAW SRM 53-00-01 FIG 201, FABRICATED DOUBLER AND FILLER IAW SRM 53-00-01 FIG 201, TREATED AND PRIMED PARTS IAW SRM 51-20-01, INSTALLED DOUBLER REPAIR IAW SRM 51-40-2, REINSTALLED INSULATION AND LINER IN AFT PIT BETWEEN BS 1360-1460 STRINGERS 22L AND 25L IAW MM 25-52-003 AND 25-50-007-4