What was found
MAIN CABIN STA 740-760 RT SIDE INBD CREASE BEAM CHORD HAS CORROSION. REMOVED CORROSION ON CREASE BEAM IAW SRM 53-30-13 ORIG THICKNESS .070, AFTER REWORK .006 WITHIN LIMITS , REMOVED CORROSION ON WEB FOUND OUT OF LIMITS IAW SRM 53-30-15 FIG. 101 DET 4, ORIG. MAT .063 AFTER REWORK .010, FABED NEW WEB IAW DWG 143-8322, LOCATED, DRILLED AND INSTALLED IAW SRM 51-40-02, MAJOR REPAIR.