What was found
AFT CARGO COMPARTMENT, FLOOR SUPPORT ANGLE CORRODED AT SPLICE LWR SURFACE AT STA 1445, RBL 16. AFT CARGO FLOOR SUPPORT SPLICE P/N 140N2749Y3 AT STA 1445, RBL 16 REMOVED AND REPLACED AS IAW SRM 51-40-02 REV 98. CORROSION REMOVED IAW SRM 51-10-02 REV 98. ORIGINAL THICKNESS 0.071" MATERIAL REMOVED 0.013", MATERIAL REMAINED 0.058" FOUND EXCEED LIMIT SRM 53-00-53 FIG 101 REV 98. THIS REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100 CRITERIA.