What was found
AFT CARGO COMPARTMENT FLOOR SUPPORT ANGLE LWR SURFACE CORRODED AT SPLICE AT STA 1445, LBL 7.55. REMOVED AND REPLACED SRM 51-40-02 REV 98. CORROSION REMOVED SRM 51-10-02 REV 98. ORIGINAL THICKNESS 0.071", MATERIAL REMOVED 0.025", MATERIAL REMAINED 0.046" FOUND EXCEED LIMIT SRM 53-00-53 FIG 101, REV 98. THIS REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100 CRITERIA.