What was found
MAIN CABIN FLOOR STR STA 324 RBL 39 TO 46 FLOORBEAM UPPER SURFACE HAS AREAS OF CORROSION. REMOVED FLOOR T-CHORD, AND ATTACHING PARTS, FABRICATED NEW TEE , WEB, & EXTRUSION. INSTALLED NEW TEE, NEW WEB, NEW EXTRUSION AND ATTACHING PARTS STA 324- 344, LBL 60-RBL 58, IAW SRM 51-40-02. CATEGORY "A", MAJOR REPAIR.