What was found
MIS-DRILLED FASTENER HOLES STA 1148 FLOORBEAM LBL 25 TO LBL 65. CUTOUT DAMAGED AREA DIMS 3 3/8" X 2", FABRICATED UPPER TEE, 2 ANGLES AND 2 REINFORCEMENT STRAPS. INSTALLED IAW SRM 53-10-8, 53-10-2, AND 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MIS-DRILLED FASTENER HOLES STA 1148 FLOORBEAM LBL 25 TO LBL 65. CUTOUT DAMAGED AREA DIMS 3 3/8" X 2", FABRICATED UPPER TEE, 2 ANGLES AND 2 REINFORCEMENT STRAPS. INSTALLED IAW SRM 53-10-8, 53-10-2, AND 51-30-2.