What was found
FWD CARGO BS 840 STR 26R TO 26L FRAME CORRODED. CORRODED STANCHION STUB BEAM (FRAME) AT BS 840 REMOVED AND REPLACED IAW SRM 51-40-02 REV. 98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100 CRITERIA.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CARGO BS 840 STR 26R TO 26L FRAME CORRODED. CORRODED STANCHION STUB BEAM (FRAME) AT BS 840 REMOVED AND REPLACED IAW SRM 51-40-02 REV. 98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100 CRITERIA.