What was found
AFT CARGO STA 1320 TO STA 1340, RBL 10 FLOOR SUPPORT PLATE CORRODED. CORROSION REMOVED IAW SRM 51-10-02 REV. 98. EVALUATED AND FOUND EXCEED LIMIT IAW SRM 53-00-04 FIG. 101 REV 98. MATERIAL REMOVED = 0.010", MATERIAL THICKNESS = 0.032", MATERIAL REMAINED = 0.022". INTERCOSTAL FABRICATED IAW DWG 146N5425 SHT 1 REV - AND PL 146N5425 REV F. INTERCOSTAL PART MARKED IAW GMM 7-0-1001. INTERCOSTAL REMOVED AND REPLACED IAW SRM 51-40-02 REV 98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100 CRITERIA.