What was found
AFTER INS FOR ALIGN - 1 MIN GOT CARGO FIRE FLASHING - PUSHED BUTTON WITH ACW PHASE ONES. REMOVED LARGE(135 LB) CARGO FIRE EXTINGUISHER BOTTLE IAW MM 26-22-01-4 (3 EA) CIRCUIT BREAKERS PULLED AND COLLARED DISCHARGE CARTRIDGES AND DISCHARGE HEADS REMOVED IAW MM. INSTALLED LARGE(135 LB.) CARGO FIRE EXTINGUISHER BOTTLE IAW MM 26-22-01. C/W UP TO AND INCLUDING STEP 3J. STILL REQUIRES CLOSING OF 3 EA CIRCUIT BREAKERS, CONTINUITY TEST AND LOW PRESSURE TEST IAW MM 26-22-01.