What was found
AFT WTB FAIRING EDGE SEALENT AREA APPROX FS 1180 TO 1320, BTW S-16L TO S-20L SKIN HAS SEVERAL GOUGES AND SCRATCH DAMAGE AREAS THAT ARE WITHIN THE "20X" DAMAGE AREA OF FASTENER. AREA IS OUT OF LIMITS IAW SRM 53-00-01, FIG. 101, DETAIL II. AFTER FURTHER EVALUATION, ABOVE NOTED AREA WAS DETERMINED TO BE WITHIN LIMITS.