What was found
DENT AT STA 1230 BETWEEN STR 25 AND 26 LT FUSELAGE ( INB OUT WITH CREASE ) CHECKED LIMITS AND FOUND OUT OF LIMITS DUE TO CREASE. REMOVED DAMAGE IAW SRM 53-00-01.INSPECTED W/ NO CRACKS FOUND. FABRICATED DOUBLER FILLER IAW SRM 53-00-01, LOCATED AND DRILLED IAW SRM 51-40-05. INSTALLED DOUBLER FILLER STA 1230, STR-25-26L, IAW SRM 53-00-01. FIRST INITIAL INSP AT 24,000 FLT CYCLES, REPEAT INSP AT 12,000 FLT CYCLE INTERVALS USING HFEC INSP METHOD. CATEGORY "B", MAJOR REPAIR.