What was found
LT WING LOWER T/E HINGE PANEL AFT OF THE NR 2 TANK SUMP DRAIN IS DENTED. (WING ROOT) ROOT) REMOVED PANEL IAW SRM 51-31-01, VOL II. EVALUATE 2 EA OUTER SKIN DENTS. THE FWD DENT MEASURES 0.033" DEEP , THE AFT DENT IS 0.043" DEEP. THE DENTS ARE LESS THAN 0.060" MAX LIMITS WITH NO DELAMINATION ARE ALLOWABLE IAW MD/DC10-10 SRM 51-80- 01, VOL II. FOUND AND REMOVED PUNCTURE DAMAGED INNER SKIN. FABBED, PREPED AND BONDED A NEW METAL SKIN PLUG AND DOUBLER IAW SRM 51-71-00, PARA 16; VOL II AND SRM 57-32-01, VOL III. ALODINED; SEALED; PRIMED AND PAINTED IAW SRM 51-21-01, VOL II; SRM 51-71-00, VOL II AND SRM 51-21-02, VOL II. INSTALLED PANEL IAW SRM 51-31-01, VOL II.