What was found
RT WING, INBD FLAP, LOWER SURFACE, OTBD WEDGE SECTION, JUST BELOW THE OUTBD HINGE FAIRING, APPROX 14 INCHES FROM THE T/E AT STA XW 273.000 HAS SKIN DAMAGE/ PUNCTURE 9" H X 10" W. REMOVED DAMAGED SKIN IAW MD/DC10-10 SRM 51-31-01, VOL II. FABRICATED NEW SKIN SECTION AND REPAIR SPLICE IAW MD/DC10-10 SRM 57-10-00, FIG 4, NOTE 4, VOL I. APPLIED ADHESIVE PRIMER TO DOUBLER, REPAIR SKIN, SPAR AND RIBS IAW MD/DC10-10 SRM 51-71-00, PARA D, VOL II. INSTALLED NEW SKIN SECTION AND REPAIR SPLICE IAW MD/DC10-10 SRM 51- 31-01, VOL II.