As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CAD DOOR ALERT PASSING 26,000 FT DESCENDED TO 8000 FT DUMPED 10,000 GAL FUEL. UNEVENTFUL LANDING. NO PRESSURIZATION PROBLEM. FOUND CONNECTOR PLUG LOOSE ON CAC DOOR SWITCH. REINSTALLED CONNECTOR PLUG IAW SMP. OPS CHECK NORMAL. ACFT OK FOR SERVICE. CLOSED