What was found
STRINGER IS CORRODED IN SEVERAL PLACES FROM BS 1341 TO 1361; STR 20L. CORROSION ON ORIGINAL STRINGER WAS FOUND OUT OF LIMITS IAW SRM 53-00-01, PG 8; VOL I. MACHINED NEW STRINGER IAW DAC DWG NR AEA 0163, REV "C". ALODINED AND PRIMED IAW SRM 51-21-01, VOL II. INSTALLED NEW STRINGER IAW SRM 51-31-01, VOL II.