What was found
LT OTBD FLAP; INBD HINGE LOCATION NR 3 MOUNTING SURFACE IS CORRODED. REMOVED CORROSION AND SOLD LIMITS IAW CMM 57-44-08. ETCHED; FLAP PEENED; CLEANED; CADMIUM PLATED AND ADHESION TESTED IAW BSOP 20-11-01. AND BSOP 20-10-02. PRIMED SURFACE; MATERIAL ID SHIMS; FABRICATED; PRIMED AND INSTALLED SHIMS IAW CMM 57-44-08.