What was found
FUSELAGE - AFT OF NOSE RADOME AT STA 305 LOWER CTR AREA WITH EXISTING BLEND OUT. EXISTING BLEND OUT AT FUSELAGE AFT OF NOSE RADOME AT STA 305, LOWER CTR AREA EVALUATED AND FOUND OUT OF LIMIT IAW SRM 53-10-00 VOL I, REV 96. ORIGINAL THICKNESS = 0.063", MATERIAL REMOVED = 0.028" AND REMAINING THICKNESS = 0.035". REPAIR CARRIED OUT IAW SRM 53-20-00 FIG 6 VOL I REV 96. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 110.