What was found
CRACK INDICATION FOUND DURING HFEC OPEN HOLE INSP ON 0.460" HOLES AT MAIN CARGO DOOR LOWER JAMB NR 4 SUPPORT FITTING AT HOLES A, B, C AND D. REPAIR CARRIED OUT AT MAIN CARGO DOOR LOWER JAMB NR 4 SUPPORT FITTING AT HOLES A, B, C AND D IAW SRM 53-50-00 FIG 17 VOLUME I REVISION 96. REPAIR CLASSIFIED AS MINOR IAW GMM 6- 2-100 REV 110.