What was found
CRACK AFT END OF STRINGER 27L AT BS 740, AC DISTRIBUTION COMPARTMENT. CUT OUT DAMAGED SECTION OF STR 27L AT BS 740, 11.5" LONG IAW SRM, REV 103, 53-10-3 FIG 1. FABRICATED STRINGER USING BAC 1498-146, 7075-T6, 11.5" LONG AND SPLICE USING BAC1498-131, 7075-T6, 9.3750" LONG, IAW SRM 53-10-3, FIG 1, DETAIL 1. INSTALLED STR AND SPLICE IAW SRM 53-10-3 FIG 1 AND 51-30-2.