What was found
CORROSION ON LOWER CHORD AT BS 950, STRINGER 30. REMOVED LOWER CHORD SPLICE AT BS950, BL 0, IAW SRM, REV 103, 51-30-2. LOCATED, DRILLED AND DEBURRED LOWER CHORD SPLICE FITTING IAW SRM 51-30-5. INSTALLED LOWER CHORD SPLICE FITTING IAW SRM 51-30-2.