What was found
CTR WING TANK - FWD UPPER PANEL 01 EACH STIFFENER CRACKED AT STR 21 'X' = -30. R & R IAW SRM 51-31-01 VOL II REV 96. NEW STIFFINER FABRICATED IAW DWG NPB6072 REVISION AL. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 110.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CTR WING TANK - FWD UPPER PANEL 01 EACH STIFFENER CRACKED AT STR 21 'X' = -30. R & R IAW SRM 51-31-01 VOL II REV 96. NEW STIFFINER FABRICATED IAW DWG NPB6072 REVISION AL. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 110.