What was found
MAIN DECK FLOOR RT SHEAR WEB INBD SUPPORT ANGLE SRA 1180 TO 1291 HAS CORROSION AND CHAFE MARKS NEAR FASTENER HOLES. REMOVED FASTENERS IAW SRM 51-40-02. REMOVED CORROSION IAW SRM 51-10-02. CHECKED LIMITS AND FOUND OUT OF LIMITS IAW SRM 53-60-13, FIG 101, DETAIL 3, PAGE 103; ORIG. MATL. = .080", REMAINING = .048", LOSS = .032". REMOVED SPLICE IAW SRM 51-40-02. REMOVED INBD ANGLE IAW SRM 51-40-02. FABRICATED INBD ANGLE, PN 1805485/ BAC 1515-553, LOCATED & DRILLED, TREATED & PRIMED IAW SRM 51-40-05 / 51-21-01. NEW INBD ANGLE MADE FROM BAC 1515-553 EXTRUSION. INSTALLED NEW INBD ANGLE, AND SPLICE IAW SRM 51-40-02, AT BS 1180-1290, LBL 64. MAJOR REPAIR.