What was found
MAIN DECK FLOOR LT SHEAR WEB INBD SUPPORT ANGLE HAS CORROSION AROUND FASTENER HOLES STA 1160-1180. REMOVED CORROSION PER SRM 51-10-02. FOUND TO BE OUT OF LIMITS PER SRM 53-40-13, P.104, DETAIL 7; BEFORE: .071", AFTER: .057", LOSS: .014". FABRICATED I/B SUPPORT ANGLE, USING PN BAC 1515-551, PER DRAWING 2312033, ON BATCH 0001805485. FOUND SPLICE CRACKED OUT OF LIMITS, BS 1080, PER SRM 53-40-13. RECEIVED SPLICE ON TRAVELER T10/842169. REMOVED AND INSTALLED LT I/B SUPPORT ANGLE, SPLICE PER SRM 51-40-02. PART MARKED BOTH SPLICE AND ANGLE PER GMM 7-0-1001. MAJOR REPAIR.