What was found
CTR WING TANK FWD UPPER PANEL 01 EACH STIFFENER CRACKED AT STR 21, "X" =30. R & R IAW SRM 51-31-01, VOLUME II, REV 96. NEW STIFFINER FABRICATED IAW DWG NPB6072, REV AL. REPAIR CLASSIFIED AS MAJOR IAW GMM 6- 2-100, REV 110.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CTR WING TANK FWD UPPER PANEL 01 EACH STIFFENER CRACKED AT STR 21, "X" =30. R & R IAW SRM 51-31-01, VOLUME II, REV 96. NEW STIFFINER FABRICATED IAW DWG NPB6072, REV AL. REPAIR CLASSIFIED AS MAJOR IAW GMM 6- 2-100, REV 110.