What was found
UPON REMOVAL OF NR 7 SLAT FOUND IB END CAP RIB CHAFED AND GOUGED, EXTERIOR SURFACE REMOVED DAMAGED IB RIB, FABRICATED NEW RIB FROM 2024O .040 APPROX DIM: 15 3/4" X 7" HEATED TREATED TO T4 CONDITION IAW FAS ENGINEERING REPORT 2-37153-801 REV A & INSTALLED NEW RIB AT NR 7 SLAT IAW SRM 51-30-2, SRM 57-50-2 FIG 2, SRM 51-20-1, SRM 51- 30-5, AND SRM 51-10-2.