What was found
CABIN RT STATION 1195 XCW=-100 - XCW=-117 CTR WING UPPER PANEL FOUND CORRODED. CORROSION REMOVED IAW SRM 51-21-01, VOL II, REV. 96. FOUND EXCEED LIMIT IAW SRM 57-20-00 FIG 8A, VOL I, REV 96.ORIGINAL THICKNESS: 0.143", REMAINING THICKNESS: 0.106", MATERIAL REMOVED 0.037". REPAIR CARRIED OUT IAW EA 8-5710-132436. REPAIR CLASSIFIED AS MINOR IAW GMM 6-2-100, REV 110.