What was found
CABIN RT STATION 1205 XCW=-100 - XCW=-117 CTR WING UPPER PANEL FOUND CORRODED. CORROSION REMOVED IAW SRM 51-21-01, VOL II, REV I 96. ORIGINAL THICKNESS = 0.142", REMAINING THICKNESS = 0.110", MATERIAL REMOVED = 0.032" FOUND EXCEEDED LIMIT IAW SRM 57-20-00, FIG 8A, VOL I, REV 96. REPAIR CARRIED OUT IAW EA 8-5710-132436, REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100, REV 110.