What was found
EXISTING REPAIR FOUND AT FORWARD CARGO COMPARTMENT FLOORBEAM FLANGE STATION 1059 RBL 24. EXISTING REPAIR FOUND AT FORWARD CARGO COMPARTMENT FLOORBEAM FLANGE STATION 1059 RBL 24. EVALUATED AND FOUND NOT IN ACCORDANCE WITH SRM REPAIR. REPAIR ON FLOORBEAM FLANGE STA 1059 RBL24 CARRIED OUT IN ACCORDANCE WITH E.A. 8-5310-140396. REPAIR CLASSIFIED AS MAJOR AS PER GMM 6-2-100 REV 110.