What was found
EXISTING FRAME REPAIR AT STA 1460 IS IAW SRM 51-70-11, FIG 1. REPAIR AND FOUND REPAIR WAS NOT COMPLIANT WITH SRM SPECIFIC REPAIR. REMOVED EXISTING IAW SRM 51-40-02. FABED REPAIR SPLICE ON STAM TRAVELER T10/844785. REPAIRED FRAME AT STA 1460 BETWEEN S-25L TO S-27L IAW SRM 53-00-07 FIG 201 REPAIR 5. THIS IS A CATEGORY "B" REPAIR WITH SUPPLEMENTAL INSPECTION DATA. DO A HFEC AND DETAILED INSPECTION AT 27,000FC AFTER REPAIR INSTALLATION OR 50,000FC WHICHEVER COMES FIRST. THERE AFTER DO AN HFEC INSPECTION AND DETAILED EVERY 12,000FC INTERVAL.