What was found
MAIN DECK STA 475, LBL 77 TO 107, FLOORBEAM IS CRACKED/DAMAGED. FABRICATED FLOORBEAM SEC REPAIR FROM 7075-T6 .071 BATCH NR 183113 IAW SRM 53-00-01, FIG 9, SHEET 7. TREATED AND PRIMED REPAIR IAW SRM 51-21-01. INSTALLED REPAIR IAW SRM 51-31-01. PAINTED AREA IAW SRM 51-21-02. CLASSIFIED AS A MAJOR REPAIR.