As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
EXISTING REPAIR AT WASTE TANK COMPARTMENT FRAME STATION 1986 L-50L TO L-50R. PRVIOUSLY ACCOMPLISHED NOT IAN ACCORDANCE WITH SRM REPAIR SCHEME. EXISTING REPAIR REMOVED AND REPLACED WITH NEW REPAIR AS PER SRM 53-30-00 FIG. 5 VOL. 1 REV. 96. EO 8-5100-7-5001 A7 PT2. REPAIR CLASSIFIED AS MAJOR AS PER GMM 6-2-100 REV 110.