What was found
STA 1500 FRAME BETWEEN STR 26L AND 27L DENTED, GOUGED AND CORRODED. REMOVED CORROSION PER SRM 51-10-02; L=3", W=1", D=.004", WITHIN LIMITS PER SRM 53-00- 53, FIG.101. GOUGE AREA; L=1.2",W=.01", D=.003", WITHIN LIMITS PER SRM 53-00-53, FIG.101; DENT OUT OF LIMITS. NO DENTS ALLOWED, IN THIS AREA, PER SRM 53-00-07, FIG.101. HFEC NOTED NO CRACKS IN CUTOUT AREA. RECEIVED NEW DOUBLER ON TRAVELER T10/846636. INSTALLED DOUBLER PER SRM 53-00-07 AT BS 1500, S26L / 27L. MAJOR REPAIR.