What was found
MCD NR2 SPOOL HAS A CRACK INDICATION AT HOLE "C". REMOVED SPOOL FITTING NR 2 IAW SRM 51-31-01, VOL II. MATERIAL ID IAW MD/DC10 SRM 53-50-00, FIG 17, VOL I. INSTALLED NEW SPOOL FITTING IAW SRM 51-33-01, VOL II, PERFORMED HFEC IAW NATSPM 06-10-01.003 ON 4 EA. MOUNT HOLES. NO CRACKS FOUND USING TNAT0010-1. MACHINED 11 EA. REPAIR BUSHINGS IAW SRM 53-50-00, FIG 17, VOL I AND EA 8-5310-1213556. BUSHING OD DIAMETER CHECK FOR PROPER INTERFERENCE FIT OF 0.0005 - 0.0015 IAW EA 8-5310-123556. INSTALLED BUSHING IAW SRM 53-50-00, FIG 17, VOL I AND EA 8-5310-123556.