What was found
OUTER PUNCTURE ON FUSELAGE SKIN AT STA 710 BETWEEN S-26R TO S-27R EVALUATED DENT, FOUND PUNCTURE OUT OF LIMITS IAW SRM 53-00-01, FIG 101, DETAIL III. REPAIRED SKIN AT STA 710, BETWEEN S-26R TO S-27R IAW SRM 53-00-01, FIG 201, REPAIR 7 CLASSIFED CATEGORY "B" REPAIR WITH INSP THRESHOLD OF 24,000 FC AND INTERVAL OF 12,000 FC.