What was found
PREVIOUS SKIN DENT AT BS 668, S19R. EVALUATED DENT L=1.3 W = 1.0 D= .033 FOUND TO BE OUT OF LIMITS DUE TO PROXIMITY TO SKIN SPLICE. CUT OUT DAMAGE & FABRICATED DOUBLER AND STRUCTURAL FILLER FROM .063 2024-T3 BATCH 1862687 AND SHIM .032 2024 - T3, BATCH 1827514 IAW EA F--5330-142246. INSTALLED REPAIR AT BS 668, JUST BELOW S19R, PER SRM 51-40-02, EA F-5330-142246, AND FAA FORM 8110-3 DATED 10/13/10. DTA IS REQUIRED NO LATER THAN 12 MONTHS FROM DATE OF 8110-3. THIS IS A MAJOR REPAIR