What was found
FWD CARGO BAY LONGERON 52 BETWEEN STA 859 AND STA 755 HAS A CRACKED FASTENER HOLE. FABRICATED NEW LONGERON IAW DWG ADA 3064 AND SRM 51-10-02, FIG 1, VOL III. ALODINED, PRIMED AND PAINTED LONGERON 52 IAW SRM 51-21-01, VOL II. INSTALLED LONGERON 52 IAW SRM 51-33-0; SRM 51-31-01, VOL II; DWG NDA 6014 AND DWG ADA 3064.