What was found
MAIN CARGO COMPARTMENT FLOORBEAM UPPER CHORD HAS CORROSION ENTIRE LENGTH BS 1660 CHECKED LIMITS STA 1660 FLOORBEAM AT LBL 55 TO RBL 59. L=6.0 W = 2.0 AND D =.038, FOUND TO BE OUT OF ALLOWABLE LIMITS IAW SRM 53-00-51 . R & R STA 1660 FLOORBEAM IAW SRM 51-40-02 , FABRICATED NEW FLOORBEAM MAT TYPE BAC 1518-338 BATCH N 1922127 IAW DWG 146N5090. THIS IS A MAJOR REPAIR.