What was found
LT HORIZ STAB RIB AT LWR STAB STA 151.81 DAMAGED. CUTOUT DAMAGED SECTION OF LT HORIZ RIB LOWER CHORD AT STAB STA 151.81, 13.6250 " LONG IAW SRM REV 103, 55-10-4 FIG 1. FABRICATED REPAIR ANGLES FROM 2024-O, .071" X 24" X 4", QTY 2, IAW SRM 55-10-4, FIG 1 AND FILLER FROM 2024T3, .063" X 13.7500" X 1.5" IAW SRM 55-10-4, FIG 1. INSTALLED REPAIR FILLER AND ANGLES IAW SRM 55-10-4, FIG 1. HEAT TREATED 2024-0 TO T4 CONDITION IAW ENGINEERING REPORT 2-37153-801, REV A.