What was found
DENT IN FUSELAGE SKIN AT STATION 475, STR 19L. EVALUATED DENT AND FOUND OUT OF LIMITS IAW SRM 53-00-01 FIG 101, TRIMMED OUT DAMAGE AND FABRICATED REPAIR DOUBLER AND REPAIR FILLER 2 AND STRUCTURAL FILLER IAW EA F-5330-143914. TREATED, PRIMED AND INSTALLED REPAIR IAW SRM 51-20-1 AND EA F-5330-143914.