What was found
PRIOR TO DESCENT FROM CRUISE, 3 LEVEL 1 ALERTS APPEARED. TANK 3 TIP TRAPPED, TANK 3 PUMP OFF, TANK 3 TRANSFER PUMP OFF. SEVERAL MINUTES AFTER INITIAL DESCENT BEGAN THE ALERTS WENT AWAY AND PUMPS BEGAN OPERATING . EMERGENCY WAS DECLARED. R & R 3 & 4K FLOAT SWITCH IAW AMM28-43-01. OPS AND LEAK CHECKED GOOD.