What was found
MAIN CARGO COMPARTMENT, FLOORBEAM UPPER CHORD HAS CORROSION AT BS 1640. REMOVED CORROSION IAW SRM 51-10-02. BLENDED AREAS; L=5.0",W=2.0",D=.035", ORIG. MATL. .125", REMAINING .090", OUT OF LIMITS IAW SRM 53-00-51, FIG.101, DETAIL 3. R & R BS 1640 FLOORBEAM FROM LBL 58.22 TO RBL 58.22, IAW SRM 51-40-02. THIS IS A CAT. "A" MAJOR REPAIR. (FLOORBEAM FABBED IAW DWG 146N5089/146N5109).